Installation and maintenance of vortex high pressure blower

Time: 2019-10-31 10:43 Browse:

Installation and use of vortex high pressure blower:

1. Install the device vertically or horizontally on a stable place to avoid the bias of back and forth due to uneven ground during operation. Ensure that the surrounding environment is clean, dry, and ventilated smoothly. If these conditions are not met, , Can take corresponding countermeasures and solutions to create more favorable conditions for longer fan operation.

2. The direction of rotation of the fan must be the same as the direction of the arrow on the fan cover. This product is not allowed to run in reverse, but it can be reversed in a short time, but it should be avoided for a long time.

3. Before using or check what kind of parameters the selected model is, so that reasonable control can be achieved during use. For example, when the fan is running, the working pressure must not exceed the rated pressure value marked on the label to avoid air pump. Excessive heat and motor overcurrent load cause damage to the motor.

4. Except for the two bearings at the motor rotor and the impeller, this type of high-pressure vortex fan does not have direct contact friction, so it will not emit object sounds or abnormal noises. If there is, it will be sucked into the interior. , Check it out.

There are two main types of bearing installation for vortex air pumps. One type of air pump end bearing is installed in the pump body between the motor base and the impeller. This type of air pump usually does not need to add grease.

Installation and maintenance of vortex high pressure blower
The picture shows 9430 model high flow industrial fan

The bearings of the second type of air pump end are installed in the middle of the pump cover. The bearings of this type of air pump end should be regularly greased (7018 high-speed grease). For three-shift air pumps, refueling times should be increased. The bearing maintenance of the fan end of this type of air pump motor is based on a type of air pump.

Maintenance and maintenance:

After the fan has been running for a long time, the filters and mufflers at both ends of the inlet and outlet air should be cleaned to prevent clogging and affect the use effect. In addition, it is recommended to use a hose connection (such as a rubber tube or a plastic spring tube) for the external connection of the air inlet and outlet. It is best not to use a hard link to avoid affecting the pipe connection when vibration occurs.

Replacement of air pump bearings: Replacement of bearings must be performed by someone familiar with repair work. First loosen the screws on the pump cover, and then remove the parts one by one in a diagonal order. The removed parts should be washed and then assembled in the reverse order.

However, it must be noted that when disassembling, the impeller and bearing cannot be pried hard, and a special Ramallah should be used. Also note that during operation, the fan is strictly forbidden from entering the pump body with solid, liquid and corrosive gases. If it is unavoidable, a special custom-made air pump can be used, and we will provide reasonable solutions and application solutions to this problem.

Installation and maintenance of vortex high pressure blower
The picture shows an explosion-proof two-stage fan

a